Lutron Electronic Enterprise Co., Ltd. was established in 1976 and has been the Taiwan's leading manufacturer in the fields of Test & Measurement Instruments for more than three decades.
Sub Categories
| Name | SKU | Description | Category | ||
|---|---|---|---|---|---|
| LUTRON PE-03K7 PH ELECTRODE + ATC TEMP. PROBE | Description: pH ELECTRODE + TEMP. PROBE Model : PE-03K7 * One kit combine pH electrode PE-03 & Temp. probe TP-07 as a whole unit. * Easy operation for the pH measurement under the ATC (Automatic Temp. Compensation). * Available for PH-208, PH-207, PH-207HA, YK-2001PH, YK-2005WA. | pH meters |
|
||
| LUTRON PE-04HD SPEAR TIP PH ELECTRODE | Description: SPEAR TIP PH ELECTRODE Model : PE-04HD * The PH-04HD spear tip pH electrode is ideal for penetration pH measurements into meats, cheese, soil and other types ofmeasurements requiring sample penetration. * pH range : 0 to 14 pH. Temp. range : 0 to 60 oC. * Size : 12 mm Dia. x 157 mm. | pH meters |
|
||
| LUTRON PE-06HD SPEAR TIP pH ELECTRODE | Description: SPEAR TIP pH ELECTRODE Model : PE-06HD * Penetration pH measurement into meats, cheese, soil and other penetration samples. * General purpose, cost effective. | pH meters |
|
||
| LUTRON PE-11 PH ELECTRODE | Description: pH ELECTRODE Model : PE-11 * General purpose, high quality, cost effective. * 1 to 13 pH (typical 0 to 14 pH). * Epoxy body, w/BNC connector. * Size : 10 mm Dia. x 128 mm. | pH meters |
|
||
| LUTRON PE-21 Industrial in line PH ELECTRODE, professional | Description: Industrial in line pH ELECTRODE, professional Model : PE-21 * Heavy duty pH electrode, design for monitoring pH value continuously in the factory and laboratory. * Range : 0 to 14 pH. * Available for pH controller, PPH-2108. | pH meters |
|
||
| LUTRON PH-04 pH 4 BUFFER SOLUTION | Description: pH 4 BUFFER SOLUTION Model : PH-04 * pH 4.00 buffer solution. | pH meters |
|
||
| LUTRON PH-07 pH 7 BUFFER SOLUTION | Description: pH 7 BUFFER SOLUTIONModel : PH-07* pH 7.00 buffer solution. | pH meters |
|
||
| LUTRON PE-01 PH ELECTRODE, 0 to 14 pH, professional | Description: PH ELECTRODE Model : PE-01 * Professional, Laboratory, highquality & field usage. * 0 to 14 pH. * Epoxy body with BNC connector. * Size : 9.5 mm Dia. x 130 mm. | pH electrodes |
|
||
| LUTRON PE-03 PH ELECTRODE, 1 to 13 pH, general purpose | Description: PH ELECTRODE Model : PE-03 * General purpose, cost effective. * 1 to 13 pH (typical 0 to 14 pH). * Epoxy body, w/BNC connector. * Body size : 12.3 mm Dia. x 160 mm. | pH electrodes |
|
||
| LUTRON PE-03K7 PH ELECTRODE + ATC TEMP. PROBE | Description: pH ELECTRODE + TEMP. PROBE Model : PE-03K7 * One kit combine pH electrode PE-03 & Temp. probe TP-07 as a whole unit. * Easy operation for the pH measurement under the ATC (Automatic Temp. Compensation). * Available for PH-208, PH-207, PH-207HA, YK-2001PH, YK-2005WA. | pH electrodes |
|
||
| LUTRON PE-04HD SPEAR TIP PH ELECTRODE | Description: SPEAR TIP PH ELECTRODE Model : PE-04HD * The PH-04HD spear tip pH electrode is ideal for penetration pH measurements into meats, cheese, soil and other types of measurementsrequiring sample penetration. * pH range : 0 to 14 pH. Temp. range : 0 to 60 oC. * Size : 12 mm Dia. x 157 mm. | pH electrodes |
|
||
| LUTRON PE-06HD SPEAR TIP pH ELECTRODE | Description: SPEAR TIP pH ELECTRODE Model : PE-06HD * Penetration pH measurement into meats, cheese, soil and other penetration samples. * General purpose, cost effective. | pH electrodes |
|
||
| LUTRON PE-11 PH ELECTRODE | Description: pH ELECTRODE Model : PE-11 * General purpose, high quality, cost effective. * 1 to 13 pH (typical 0 to 14 pH). * Epoxy body, w/BNC connector. * Size : 10 mm Dia. x 128 mm. | pH electrodes |
|
||
| LUTRON PE-21Industrial in line PH ELECTRODE, professional | Description: Industrial in line pH ELECTRODE, professional Model : PE-21 * Heavy duty pH electrode, design for monitoring pH value continuously in the factory and laboratory. * Range : 0 to 14 pH. * Available for pH controller, PPH-2108. | pH electrodes |
|
||
| LUTRON PI-06 PHOTO SENSOR for PANEL TACHOMETER | Description: PHOTO SENSOR ( Photo Interrupter ) Model : PI-06 * Photo interrupter or the photo sensor for DT-2240D, PDT-2250, TR-RPM1A4. * Power supply : DC 12V to 30V. * 3 wires : Power, Signal and Ground. | Photo sensor (Photo interrupter) |
|
||
| LUTRON AP-9V110 DC 9V POWER ADAPTER | Description: DC 9V POWER ADAPTER Model : AP-9V110 * Input voltage : 110/120 ACV, 50/60 Hz.* Output voltage : DC 9V/0.5 Amp. rating.* Output plug : round 2.5 mm diameter.* Linear transformer type. | Power adaptor |
|
||
| LUTRON AP-9V220 DC 9V POWER ADAPTER | Description: DC 9V POWER ADAPTER Model : AP-9V220 * Input voltage : 220/230 ACV, 50/60 Hz.* Output voltage : DC 9V/0.5 Amp. rating.* Output plug : round 2.5 mm diameter.* Linear transformer type. | Power adaptor |
|
||
| LUTRON AP-GTE PLUG CONVERTER | Description: PLUG CONVERTERModel: AP-GTE* Convert the input plug of AP-9V220 from the Germany type to UK (England) type. | Power adaptor |
|
||
| LUTRON DW-6090A POWER ANALYZER, bench type | Description: POWER ANALYZER, Bench type Model : DW-6090A * Large LCD, multi-displays. * True rms for WATT, ACV, ACA. * Watt, VA, Power factor, ACV, ACA, VAr, Whr, DCV, DCA, ohms, RS-232. * Accept current probe & CT input. Battery power. | Power analyzers, Watt meters |
|
||
| LUTRON DW-6092 3 PHASE POWER ANALYZER | Description: SD card real time data recorder,3 PHASE POWER ANALYZERModel : DW-6092* 3 phase/4 wire, 3 phase/3 wire, 1 phase/2 wire, 1 phase/3 wire* True rms measurement for ACA, ACV.* True power : W, KW, MW.* VA, KVA, MVA, VAR, KVAR, MVAR.* PF (power factor), phase angle.* KWH, KVAH, KVARH, PFH.* Voltage measurement range: 10 to 600 ACV* Current measurement range: 0.2 A to 1200 ACA.* Programmable CT ratio (1 to 600) and PT ratio (1 to 1000).* Real time data recorder with SD card.* RS232/USB... | Power analyzers, Watt meters |
|

