TES-1381 Conductivity & pH/ORP Meter
|
|
pH, mV, Conductivity, TDS, Resistivity, Salinity, Concentration and Temperature measurement functions.
0.001pH, 0.1mV, 0.001µS/cm, 0.001mg/L and 0.1°C / °F Resolution.
Programmable Temperature Coefficient for conductivity measurement.
Auto / Manual Temperature Compensation for pH and conductivity measurement.
Practical Salinity in the Range of 0 to 42.0, in accordance with UNESCO data measurement.
Dual display with temperature Simultaneously.
Easy & Fast to operate.
Ideal for... |
PH Tester
|
|
|
|
PROVA-8500 Energy-Saving Tester
|
|
Standby power measurement ( 0 to 100W width 0.001W resolution)
Regular power(0~2000W)
100W AC power supply + AC power analyzer]
Programmable nominal output (85V to 250V , 45Hz to 65Hz)
power quality measurement (W , PF , V , A)
PC programmable through RS-232C interface( Optional RS-232C to USB bridge)
Programmable Over current protection (OCP)
Memory of 99 preset voltage and frequency
Standby and Operation Button
Back space for easy correction
Standby power measurement of note... |
Power Analyzer
|
|
|
|
WM-01/02 Power Analyzer Datalogger
|
|
4 LCD Displays with W, PF, V, A
Easy Plug-in and Test
RS-232 Computer Interface
|
Power Analyzer
|
|
|
|
TES-3096 DC/AC KW CLAMP METER
|
|
Compact Size
Trms KW measurement
AC/DC Current Measurement (AC 600A/DC 600A)
600V AC & 600V DC, Ohm/Continuity Beeper
600 V AC & 600 V DC. Ohm/Continuity Beeper
One Touch DCA Zero
|
Power Clamp Meter
|
|
|
|
AC Voltage (50Hz to 400 Hz):Trms Range Resolution Accuracy Sensitivity Overload Protection 999.99 mV 0.1mV ±1% ± 0dgts(50,60Hz) ±2%±20dgts(40~100Hz) 2.0mV 600V 9.999 V 1mV 0.020V 99.99V 10mV ±1% ± 20dgts(50,60Hz) ±2% ±20dgts(40~
|
|
3-3/4 Digital LCD, 4000 count, Autoranging.
Trms KW, Current, Voltage measurement.
AC Current 0.1A to 700A.
Resistance and Continuity test.
Data hold & MAX function.
Pocket size.
Auto Power off.
IEC1010-1 CAT III 600V
|
Power Clamp Meter
|
|
|
|
TES-3079K Power Clamp Meter
|
|
HVAC Application:
Check current draw in motors and compressors.
Use MAX/MIN/Recording in the temperature mode to assess efficiency.
Test run/start capacitors.
Confirm low voltage control signals.
Measure flame safeguard device current draw.
Confirm power sources.
Analyze temperature and voltage or current data with the aid of the time stamp.
Insulation test up to 100M Ω.
Electrical Application:
Check for energized circuits and balance loads.
1 Φ /3 Φ (3P3W/3P4W)Power... |
Power Clamp Meter
|
|
|
|
TES-3063/3064 Power AC/DC Clamp Meter
|
|
1 Φ 2W, 1 Φ 3W,3 Φ 3W,3 Φ 4W
RS-232 interface to talk with PC
4 digits with dual display LCD
Amp / Voltage f requency measurement
Dual display KW+PF , KVA+PF , V+A
4000 continuity point data logger , 25 point manual data logger
True power / apparent power / power factor measurement
True RMS. V , A , W , cap , lnd , phase indicator
MIN / MAX measurement
Peak hold detector
Dual display A+Hz , V+Hz
EN61010-1 600V Installation CAT III Pollution Degree 2 |
Power Clamp Meter
|
|
|
|
PROVA-6601 3 Φ PF Power Clamp
|
|
PF( 3 Φ 3W , 3 Φ 4W 1Φ 2W )
AC+DC 2000A, 600V Power Factor
AC+DC 1200KW(1 Φ ) AC+DC 200KW(3Φ )
AC/DC Auto Detection
Dual Display V+Hz, A+V,KW+PF,KVA+KVAR
|
Power Clamp Meter
|
|
|
|
PROVA-6600 3 Φ Power Clamp
|
|
3 f 4W, 3 f 3W, 3 f Balanced, 1 f 2W, and 1 f 3W Power Measurement.
AC+DC true power, and True RMS AC Voltage and Current
AC+DC 2000A, AC 600V, DC 800V
AC+DC 1200KW(1 f ), AC+DC 2000KW (3 f )
Dual Display V+Hz, A+Hz, W+PF, KVA+KVAR, V+A
Phase Angle Measurement
3 f RST(L1L2L3) Sequence Indication.
Memory of 4 records.
DCA/DCW Auto Zero when power clamp powering on.
AC/DC Auto Detection.
Auto range.
|
Power Clamp Meter
|
|
|
|
PROVA-8000 Programmable Power Supply
|
|
Over-Voltage , Over-Current Protection
Built-in Buzzer Alarm
Easy RECALL and STORE functions
Stby / Operate Button
English-like RS-232C commands
OCP With Programmable Timer
200 Sets of Memory
AUTO-STEP function with programmable interval
Bi-direction RS-232C interface
3.8 kg / 8.4 Lbs weight
|
Power Supply / Inverter
|
|
|
|
RM-1500/1501 Digital Tachometer
|
|
5 Digits LCD Display
Light Reflex Measurement
Range 10.00 to 99,999 RPM
Measuring Distance 50 to 300mm
Event counter with elapsed time
RM-1502 optional Contact Adaptor
Max / Min / Hold : True Average
Auto Range RPM
RS-232 Interface for Model RM-1501
Contact RPM and circumferential velocity measurements in one simple adaptor(RM-1502)
|
Tachometer
|
|
|
|
RM-1000 Digital Optical Tachometer
|
|
Direct Light-Beam Sensing
Range: 10-100,000RPM
Memory: Max, Min, 0
|
Tachometer
|
|
|
|
TES-1326S/1327/1327K Infrared Thermometer
|
|
0.1 ℃/0.2 ℉ Resolution
-35 ℃ ~ 500℃ (-31 ℉ ~ 932 ℉ )
Built-in Laser Targeting / Backlight LCD display
MAX / MIN function
Data memory and read function
Dual thermometer and Dual display (1327K)
Audible and visible alarm (1327/1327K)
Emissivity adjustable (1327/1327K)
|
Thermometer/Infrared Thermometer
|
|
|
|
TES-1319 Thermometer
|
|
Type "K" Thermocouple Input.
Switchable Resolution 0.1° / 1 ° .
With ℃& ℉ switching.
Max / MIN Function.
Data Hold Function.
Flip-up stand.
|
Thermometer/Infrared Thermometer
|
|
|
|
TES-1317/1318 Platinum RTD Thermometer
|
|
Pt 3916/3926/385 RTD standard.
7500 DataLogging capacity. (1317)
Warning beeper with HI/LO setting.
Time setting.
MAX / MIN with TIME, MAX-MIN AVG Hold function.
℃ / ℉ / K User-Selective.
Back - Light LCD display.
Dual input function T1/T2 temperature display. (1318)
|
Thermometer/Infrared Thermometer
|
|
|
|
TES-1315/1316 K.J.E.T.R.S.N. Data-Logger Thermometer
|
|
Highly accurate thermometer with thermocouple K, J, E, T, R, S, N type.
Dual input function T1/T2 temperature display. (1316)
7500 DataLogging capacity.
Warning beeper with HI/LO setting.
MAX/MIN with TIME, MAX-MIN AVG, HOLD function.
℃ / ℉ / K User-Selective.
Back-Light LCD display.
|
Thermometer/Infrared Thermometer
|
|
|
|
TES-13131/1314 K.J.T.E.R.S.N. Thermometer
|
|
Highly accurate thermometer with thermocouple K, J, E, T, R, S, N type.
Dual input function T1/T2 temperature display. (1314)
Warning beeper with HI/LO setting.
MAX/MIN with TIME, MAX–MIN AVG, HOLD function.
℃ / ℉ / K User-Selective.
Back-Light LCD display.
|
Thermometer/Infrared Thermometer
|
|
|
|
TES-1311/1312A Thermometer
|
|
Type "K" Thermocouple Input
Switchable Resolution 0.1° / 1°
With℃& ℉ switching
Max / MIN Function
Data Hold Function
Room Temperature Compensated
T1 & T2 dual points display
T1 - T2 differential measurement
Flip-up stand
Backlight LCD display
|
Thermometer/Infrared Thermometer
|
|
|
|
TES-1310/1320 Thermometer
|
|
Switchable Resolution 0.1° /1.0 °
Single/Dual Channels with Differential Measurements
Data Hold Function
|
Thermometer/Infrared Thermometer
|
|
|
|
TES-1307 Datalogging K/J Thermometer
|
|
K/J Type thermocouple input
Auto ranging
Dual display LCD
8000 Record Data logging Capacity
Maximum / Minimum / Average reading
Relative reading
RS-232 interface (software include)
|
Thermometer/Infrared Thermometer
|
|