Kyoritsu 2433 Frequency Selector Switch to eliminate the effect of harmonics. • Three AC current ranges : 40mA/400mA/400A. Leakage Clamp Meters
Kyoritsu 2433R Frequency Selector Switch to eliminate the effect of harmonics. • Three AC current ranges: 40mA/400mA/400A. Leakage Clamp Meters
Kyoritsu 2434 Least affected by external stray magnetic field. • 20mA AC max. in proximity to a 15mm-dia conductor carrying 100A AC • Frequency Selector Switch to eliminate the effect of harmonics. Leakage Clamp Meters
Kyoritsu 5010 (for Current) / 5020 (for Current & Voltage) 3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage • Power Quality analysis(only on KEW 5020)(Power Quality:Reference voltage, Swell, Dip, Short power Interruptions)   Large Capacity for storing 60,000 data points 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded   Lowpass Filter will filter out the... Logger
Kyoritsu 5001 THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT60,000 DATA IS RECORDED 60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel Continuous measurement time   About 40 days   Data where it doesn’t disappear even if battery is consumed   Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged.... Logger
Kyoritsu 8309 Floating voltage can be measured *Floating voltage:phase to phase voltage not grounded *KEW 5020-01:KEW 5020 logger with KEW 8309 (1 pce.) For use with following model 5020 Voltage Sensor
Kyoritsu 8130 Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at the sensor part • Designed to meet the international safety standardIEC 61010-1 CAT IV 300V, CAT III 600V Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 Flexible Clamp Sensor
Kyoritsu 8129 Flexible for various test fields • Can measure AC current up to 3000A • Flexible and light weight by the air core coil used at the sensor part • Measurable conductor size:max Φ150mm • Designed to meet the international safety standardIEC 61010-1 CAT.III 600V Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 Flexible Clamp Sensor
Kyoritsu 8121 Applicable model 5010/5020 Conductor size Φ24 Rated current AC 100A Output voltage AC 500mV/100A (AC 5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 9.5Ω Applicable standards IEC 61010-1:2001,IEC... Load current clamp sensors
Kyoritsu 8122 Applicable model 5010/5020 Conductor size Φ40 Rated current AC 500A Output voltage AC 500mV/500A (AC 1mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.9Ω Applicable standards IEC 61010-1:2001,IEC... Load current clamp sensors
Kyoritsu 8123 Applicable model 5010/5020 Conductor size Φ55 Rated current AC 1000A Output voltage AC 500mV/1000A (AC 0.5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.5Ω Applicable standards IEC 61010-1:2001,IEC... Load current clamp sensors
Kyoritsu 8146 Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Conductor size Φ24 Rated current AC 30A Output voltage AC 1500mV/30A (AC 50mV/A) Accuracy 0~15A|±1.0%rdg±0.1mV (50/60Hz)|±2.0%rdg±0.2mV (40Hz~1kHz) 15~30A|±5.0%rdg (50/60Hz)|±10.0%rdg (45Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~50ºC, less than... Leakage & Load current clamp sensors
Kyoritsu 8147 Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Leakage & Load current clamp sensors
Kyoritsu 8148 Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Leakage & Load current clamp sensors
Kyoritsu 8141 Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement. Leakage current clamp sensors
Kyoritsu 8142 Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement. Leakage current clamp sensors
Kyoritsu 8143 Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement. Leakage current clamp sensors
Kyoritsu 3321A AC Voltmeter with linear, easy-to-read scales. • Auto discharge function; any charge stored in the circuit under test will be automatically discharged after testing. • Designed to meet IEC/EN 61010-1 CAT.III 600V, CAT.II 1000V • Color-coded scales for easy reading. • Back light function to facilitate working at dimly illuminated locations. • Test lead set with remote control switch. • Shoulder strap for hands free. Analogue Insulation Tester
Kyoritsu 3161A Miniature lightweight insulation tester. It weighs only 340g(battery included), but carries full measurement functions. • Automatic discharge of circuit capacitance. • Test leads with remote control switch. • New robust housing case. • Back light function. • Neck strap for both hand?s operation. Analogue Insulation Tester
Kyoritsu 3165/3166 500V/1000MΩ(Model 3165) • 1000V/2000MΩ (Model 3166) • Expanded megohm scale for easy reading. • New robust housing case to prevent damage. • AC voltmeter scale for easy reading. • Neck strap for both hand’s operation. Analogue Insulation Tester