Products

  • Filter
  Name SKU Description Category
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamps
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamps
Fluke 3583R Split-Core Current Transformers Current range: 0.01 – 10A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamps
Fluke 3584R Split-Core Current Transformers Current range: 0.1 – 40A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamps
Fluke 3585R Split-Core Current Transformers Current range: 0.5 – 1-0A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamps
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamps
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamps
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamps
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamps
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamps
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamps
Fluke FOM Fiber Optic Meter The compact FOM plugs into your DMM and makes testing in tight spaces easy A variety of light sources (FOS 850, FOS 1300, and FOS 850/1300) and patch cords (ST to ST, ST to FC, ST to SC, ST to SMA) let you get just what you need for testing different cable types and lengths Highly accurate readings mean less work, less repeated testing Input connector: fixed ST Battery life: 16 hours minimum, 9V alkaline LED low battery indicator Operating temperature: 0°C to +40°C (32°F to... Fiber Optics
Fluke FOS-850 Fiber Optic Light Source A variety of light sources allow you to test different cable lengths. One year warranty Fiber Optics
Fluke FOS-850/1300 Fiber Optic Light Source A variety of light sources allow you to test different cable lengths. One year warranty Fiber Optics
Fluke CO-205 Aspirator Kit The CO-205 accessory kit includes: Stainless steel sampling tube Industrial-grade hand operated aspirator to draw flue sample Easy to replace particulate filter Specially designed nose cap for connection to the Fluke CO-210/220 4' (1.2m) hose length Gas Measurement
Fluke 80K-6 High Voltage Probe A high voltage probe that allows a multimeter to measure up to 6,000V respectively. Intended for low energy applications only One year warranty High Voltage Probes
Fluke 80K-15 High Voltage Probe Voltage Range: 0 to 15kV DC or peak AC, 10kV rms  AC Basic Accuracy: DC +/- 2% 60Hz: +/- 5% Division Ratio: 1000:1 Safety Standards: IEC 1010-2-031:1993, Type B, 40 kV DC or peak AC, 28kV rms AC, Overvoltage Category I (voltage derived from limited energy transformer). Input Resistance: 1000 Megohm Required Meter Input Resistance: 10 Megohm High Voltage Probes
Fluke 80K-40 High Voltage Probe A high voltage probe that allows a multimeter to measure up to 40,000V respectively. Intended for low energy applications only One year warranty High Voltage Probes
Fluke L200 Probe Light Small, rugged light easily attaches to any Fluke test probe Bright white LED illuminates contact area Frees both hands for work 120 hours of battery life Uses 2 3-volt watch batteries Lights for Probes and Hats
Fluke L205 Mini Hat Light Attaches to a baseball hat - includes hat clip Electrically and thermally nonconductive Withstands 6' drops to concrete Waterproof Rugged ABS case won't crack or chip Bright xenon lamp in a prefocused optical quality reflector Lights for Probes and Hats