Fluke 117/323 Electricians Multimeter Combo Kit True RMS Multimeter and Clamp Meter Kit Fluke 117 Digital Multimeter. VoltAlert™ technology for non-contact voltage detection. AutoVolt automatic ac/dc voltage selection. Low input impedance: Helps prevent false readings due to ghost voltage. Large white LED backlight to work in poorly lit areas. True-rms for accurate measurements on non-linear loads. Measures 10 A (20 A overload for 30-seconds). Resistance, continuity, frequency and capacitance. Min/Max/Average to record signal fluctuations. Compact ergonomic design for... Combo Test Kits
Fluke 80PK-11 Type-K Flexible Cuff Thermocouple Temperature Probe Designed for hands free measurement of HVAC temperature measuring applications Use multiple and leave in place for route based routine maintenance Use with any temperature-measuring instrument designed to accept Type-K thermocouples Combo Test Kits
Fluke TPAK ToolPak, Meter Hanging Kit Kit includes: 9 inch hook and loop strap, universal hanger clip, hook hanger for non magnetic surfaces and a strong magnet.  Solves almost any hanging and positioning problem you may face. The universal hanger allows you to hang your meter on nails, hooks and many other objects. Compatible with many Fluke instruments. One year warranty. Combo Test Kits
Fluke 80BK-A Integrated DMM Temperature Probe Type-K thermocouple with standard shrouded banana jack Convenient one piece construction Compatible with DMMs with temperature measurement functions Measurement range:-40 to 260ºC One year warranty Combo Test Kits
Fluke 80AK-A DMM Thermocouple Adapter Adapts Type-K thermocouple mini-connector to dual banana plug inputs Measurement range and accuracy: probe dependent Suitable for low voltage applications (below 30 V AC, 60 V DC) One year warranty Combo Test Kits
Fluke C115 Soft Carrying Case Includes two padded pockets for protection of two test tools, such as a digital multimeter and 60 Series IR thermometer and a pouch for test leads and other accessories. Durable polyester 600D case construction for long life. Compatible with Fluke 20, 70, 11X, 170 Series digital multimeters and other similar format test tools. One-year warranty. Combo Test Kits
Fluke 116 HVAC Multimeter with Temperature and Microamps Built in thermometer for HVAC applications Microamps to test flame sensors LoZ: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak™) CAT III 600 V safety rated Combo Test Kits
Fluke 62 Max+ Infrared Thermometer with Dual-point Laser Sighting 30°C to 650°C, 12:1 ratio, ±1% Accuracy Wide temperature range from -30° to 650°C (–20° to 1202°F) 12:1 distance-to-spot ratio ±1% Accuracy of the reading. Dual lasers to accurately identify spot size Rugged performance Survives 9.8 foot/3 meter drops to wood floors Water and dust resistance IP54 rated to withstand rain, splashing liquids, dust and dirt Small and easy to use Ergonomic fit to "feel" good in your hand Multi-angle Backlit display Combo Test Kits
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke 3585R Split-Core Current Transformers Current range: 0.5 – 1-0A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3584R Split-Core Current Transformers Current range: 0.1 – 40A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3583R Split-Core Current Transformers Current range: 0.01 – 10A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3300 Clamp-on Current Transformer Current range: 10-3000A Accuracy: 2% RDG +/- 0.05% FS Frequency response: 5 kHz Jaw opening: 3.5 x 4.5” dia. (9 x 11 cm) Current Clamp DMM Accys