Fluke Bronze Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Bronze CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years.
Bronze CarePlan features
One to Three year extended warranty coverage beyond your original factory warranty
Performance check on needed repair
First-on-Bench priority handling
Discount on... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
|
Fluke Silver Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Silver CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years.
Silver CarePlan features
One to Three year extended warranty coverage beyond your original factory warranty
One performance check included during your extended warranty period
Full... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
|
Fluke Priority Gold Instrument CarePlan For Thermal Imagers
|
|
Repairs are always unexpected, and they can be costly. Keep your camera in top operating condition and control your cost of ownership with a Fluke Gold CarePlan. Maintain you camera in peak operating condition and protect your investment beyond your factory warranty for up to three additional years.
Priority Gold CarePlan features
One to Three year extended warranty coverage beyond your original factory warranty
Loaner camera on extended repair
One NIST traceable calibration included... |
Instrument CarePlans (for Thermal Imagers)
|
|
|
|
Fluke TP38 Slim Reach Test Probe Set
|
|
One pair (red, black) of slender probe bodies for probing closely spaced or recessed terminals
Hard stainless steel probe tips
Insulated Probe Tip (Designed To Meet GS38 Specs for United Kingdom)
CAT IV 600 V, CAT III 1000 V, 10 A rating. UL listed
One year warranty
|
Options
|
|
|
|
Fluke SCC198 Automotive Troubleshooting Kit (190 Series)
|
|
The SCC198 Automotive troubleshooting kit includes:
C190 Hard-shell Carrying Case for 190-Series ScopeMeter
SW90W FlukeView ScopeMeter Software package
OC4USB Serial Interface Cable for connecting the ScopeMeter to a (notebook) PC
STL90 Shielded Test Leads (1 red & 1 gray) with 2 ground leads
Four Backprobe pins (1 red, 1 gray, 2 black),
Four 4 mm Tip adapters (1 red, 1 gray, 2 black),
AC85A Sets of Alligator Clips (Four pieces, 1 red, 1 gray, 2 black)
C75 Softcase, for... |
Options
|
|
|
|
Fluke SCC128 Automotive Troubleshooting Kit (120 Series)
|
|
The SCC128 Automotive troubleshooting kit includes:
C120 Carrying Case for 120-Series ScopeMeter
SW90W FlukeView ScopeMeter Software package
OC4USB Serial Interface Cable for connecting the ScopeMeter to a (notebook) PC
STL90 Shielded Test Leads (red & gray) with 2 ground leads
Four Back probe pins (1 red, 1 gray, 2 black),
Four 4 mm Tip adapters (1 red, 1 gray, 2 black)
AC85A Sets of Alligator Clips (Four pieces, 1 red, 1 gray, 2 black)
TL24 Ground lead with banana plugs (1... |
Options
|
|
|
|
Fluke PM9091/001 50 Ohm Coaxial BNC cable set (3 x 1.5m)
|
|
Each set consists of three black cables with colored BNC male connectors (red, gray and black) for easy identification
Cable length is 1.5 m
Maximum Signal Voltage: 300 V rms
Maximum Voltage to Ground: 600 V rms CAT III per IEC 61010-031
BB120 Shielded Banana to BNC Adapter is required to adapt to ScopeMeter 120 Series shielded banana jack inputs.
|
Options
|
|
|
|
Fluke PM9082001 Dual Banana Plug (female) to Male BNC Adapter
|
|
The set consists of two adapters
One red (signal) and one black (ground) 4-mm banana contact
Maximum Signal Voltage: 600V rms
Maximum Voltage to Ground: 600V rms. CAT III per IEC 61010-031
|
Options
|
|
|
|
Fluke PM9081001 Dual Banana Plug (male) to Female BNC Adapter
|
|
Dual Banana Plug 4 mm male to female BNC Adapter
Consists of two adapters
Maximum Signal Voltage: 300V rms
Maximum Voltage to Ground: 600V rms
CAT III per IEC 61010-031
|
Options
|
|
|
|
Fluke H3 Clamp Meter Holster
|
|
Fabric holster absorbs shocks and protects meter from rough handling
Built-in pocket for lead storage Convenient belt-loop with snap
One year warranty
|
Options
|
|
|
|
Fluke BB120 Shielded Banana to Female BNC Adapter
|
|
Maximum Signal Voltage: 300V rms CAT III per IEC 1010-02-031
Maximum Voltage to Ground: 600V rms. CAT III per IEC 1010-2-031
|
Options
|
|
|
|
Fluke 71X Hose Kit
|
|
Compatible with the 717 and 718 calibrators 100 PSI and below
The kit contains:
three translucent hoses one meter long
easy to connect push fit connectors for both connect ion to the calibrator and the device under test
one 1/8 to ¼ NPT female-female adapter.
|
Pressure
|
|
|
|
Fluke 700PTP-1 Pneumatic Test Pump
|
|
Pump can be easily cleaned without disassembly
The vernier can be used as a stand-alone low pressure calibration source
Two pressure ports allowing simultaneous connection
¼ -NPT female fitting for the reference gauge or pressure module
¼” NPT female fitting for the unit under test
Adjustable stroke length can be set to limit the pressure per stroke
Includes
1/4 in NPT male to 1/4 in BSP female
1 meter of hose
(2) 1/8 in NPT male quick connects
1/8 NPT female to 1/4 in... |
Pressure
|
|
|
|
Fluke 700PRV-1 Pressure Relief Valve Kit
|
|
Adjustable from 725 to 5800 PSI (50 to 200 bar)
Preset at 2,900 psi/200 bar)
Repeatability to 10% of nominal setting.
Installs directly into the 700HTP-1 pump
|
Pressure
|
|
|
|
Fluke 700LTP-1 Low-pressure Test Pump
|
|
Pump can be easily cleaned without disassembly.
Adjustable pressure relief valve with slow-bleed capability.
Allows the slow release pressure at a controlled rate
Quick fit connectors, one for the reference port for connection to a Fluke 700 series pressure module and one to connect to a unit under test
Slim design, easy to carry and use
Includes:
(2) adapters to convert the reference and UUT port hose fitting to 1/4" BSP female
Adapter to convert the reference port hose... |
Pressure
|
|
|
|
Fluke 700HTH1 Hydraulic Test House
|
|
Hose and fittings to connect directly to the Fluke 700HTP-1 test pressure port Includes plugs and caps to eliminate fluid loss in hose, eliminates the need to re-prime the hose.
Self-sealing fittings with easy finger tight connections.
Low volumetric expansion and a negligible pressure drop at rated pressures
One year warranty
Includes:
Hose with (2) 1/4" NPT female output connections
(2) adapters that to convert ¼: NPT female to 1/4" NPT male (include sealing caps)
1/4... |
Pressure
|
|
|
|
Fluke 700PMP Pressure Pump
|
|
The Fluke 700PMP is a hand-operated pressure pump to provide pressures up to 150 psi/1000 kPa.
Output fitting is 1/8 FNPT
Linear stroke of 4 cm.
Multi-turn venire for fine adjustment of pressure.
One year warranty
|
Pressure
|
|
|
|
Fluke 700PCK Pressure Calibration Kit
|
|
The Fluke 700PCK makes it possible to calibrate your pressure modules at your facility using your own precision pressure standards.
When installed on your PC, the Windows T-based software easily steps you through an as-found verification, a calibration adjustment, and an as-left verification.
Calibration data is captured for import to your database.
A 386 or better PC running Windows 3.1 or better is required, along with a precision pressure standard with an uncertainty of less than 1/4... |
Pressure
|
|
|
|
Fluke 700P31 Gauge Pressure Module
|
|
Display pressure readings in any of 10 different pressure units you specify in the calibrator setup
Rugged urethane molded case protects the module from rough handling and harsh conditions
Features internal temperature compensation from 0°C to 50°C for full-accuracy performance
Includes NIST-traceable calibration certificate
Module can be calibrated locally using the Fluke 700PCK Pressure Calibration Kit, a PC, and a precision pressure source
One year warranty
|
Pressure
|
|
|
|
Fluke 700P30 Gauge Pressure Module
|
|
Display pressure readings in any of 10 different pressure units you specify in the calibrator setup
Rugged urethane molded case protects the module from rough handling and harsh conditions
Features internal temperature compensation from 0°C to 50°C for full-accuracy performance
Includes NIST-traceable calibration certificate
Module can be calibrated locally using the Fluke 700PCK Pressure Calibration Kit, a PC, and a precision pressure source
One year warranty
|
Pressure
|
|